VA 550 Insertion Type Flowmeters
Flow Thermal
Flow sensor for installation in existing compressed air or gas line of 3/4" to 40"
Housing rotatable, display 180º rotatable (on the head). Settings can be modified via display, flow meter can be reset
Housing rotatable, display 180º rotatable (on the head). Settings can be modified via display, flow meter can be reset
Unit of Measure
Items |
![]() 0695 0550 VA 550 Insertion Type Flowmeter Web Price QUOTE
|
![]() 0553 0108 5 Meter (m) Length Connection Cable Web Price QUOTE
|
![]() 0553 0109 Connection Cable for 32.81 Feet (Ft) Length Probes with Open Ends Web Price QUOTE
|
![]() 0553 2503 16 Feet (ft) Length Ethernet Connection Cable Web Price QUOTE
|
![]() 0553 2504 32 Feet (ft) Length Ethernet Connection Cable Web Price QUOTE
|
|||||
Description |
N/A
Flow sensor for installation in existing compressed air or gas line of 3/4" to 40" Housing rotatable, display 180º rotatable (on the head). Settings can be modified via display, flow meter can be reset |
N/A Connection cable for probes 5 m, with open ends | N/A Connection cable for probes 32.81 ft with open ends | N/A Ethernet Connection Cable Length 16 Ft, M12 Plug X-coded (8 Pin) To Rj 45 Plug | N/A Ethernet connection cable length 32 ft, M12 plug x-coded (8 pin) to RJ 45 plug | |||||
Approve Payments |
N/A
Finance with Approve Payments |
|||||||||
Measuring Range | N/A Up to 164 ft/s, Low-Speed Version Up to 304 ft/s, Standard Version Up to 607 ft/s, Maximum Version Up to 735 ft/s, High-Speed Version | N/A | N/A | N/A | N/A | |||||
Note for Measuring Range |
N/A
Measuring range SCFM for different pipe diameters and gases All measured values related to DIN 1343 standard conditions 0º and 1013 mbar ex works. |
N/A | N/A | N/A | N/A | |||||
Accuracy | N/A ± 0.3% of Full Scale (F.S.) ± 1.5% of Measured Value (M.V.) | N/A | N/A | N/A | N/A | |||||
Accuracy on Request | N/A ± 1.0% of Measured Value (M.V.) ± 0.3% of Full Scale (F.S.) | N/A | N/A | N/A | N/A | |||||
Accuracy Indications | N/A Relative to Ambient Temperature 71.6 ºF +2 ºF, System Pressure 87 psi | N/A | N/A | N/A | N/A | |||||
Repeatability | N/A 0.25% of Measured Value (M.V.) in Case of Correct Mounting (Mounting Aid, Position, Inlet Section) | N/A | N/A | N/A | N/A | |||||
Measuring Principle | N/A Thermal Mass Flow Sensor | N/A | N/A | N/A | N/A | |||||
Response Time | N/A t 90 <3 sec | N/A | N/A | N/A | N/A | |||||
Operating/Ambient Temperature Range | N/A -4 to 158 ºF | N/A | N/A | N/A | N/A | |||||
Media Temperature Range | N/A -4 to 356 ºF | N/A | N/A | N/A | N/A | |||||
Media Temperature Range (ATEX Version) | N/A -4 to 248 ºF | N/A | N/A | N/A | N/A | |||||
Adjustment Possibilities via Display, External Hand- Held Device PI 500, PC Service Software, Remote Diagnosis | N/A Nm³/h, Nm³/min, Nl/min, l/s, ft/min, cfm, kg/h, kg/min, inner diameter, reference conditions ºC/ºF, mbar/hPa, zero point correction, leak flow volume suppression, scaling analog output 4...20 mA, pulse/alarm, error codes etc. | N/A | N/A | N/A | N/A | |||||
Standard Outputs | N/A 1 x 4 to 20 mA Analog Output (Electrically Not Isolated) Pulse Output RS 485 (Modbus-RTU) | N/A | N/A | N/A | N/A | |||||
Optional Outputs | N/A 2 x 4 to 20 mA Active HART M-Bus Mod- bus TCP Profibus DP Profinet | N/A | N/A | N/A | N/A | |||||
Burden | N/A <500 Ω | N/A | N/A | N/A | N/A | |||||
Additional Average Value Calculation | N/A For all parameters freely adjustable from 1 minute up to 1 day, e. g. 1/2 hours average value, average day value | N/A | N/A | N/A | N/A | |||||
Protection Class | N/A Ingress Protection (IP 64) for ATEX II 2D Ex tb IIIC T90ºC Db Ingress Protection (IP 67) | N/A | N/A | N/A | N/A | |||||
Housing Material | N/A Die-Cast Aluminum | N/A | N/A | N/A | N/A | |||||
Sensor Tube Material | N/A Stainless Steel 1.4404 | N/A | N/A | N/A | N/A | |||||
Screw-In Thread | N/A G 1/2 in. (International Organization for Standardization (ISO 228)) National Pipe Thread (NPT) 1/2 in. PT 1/2 in. R 1/2 in. | N/A | N/A | N/A | N/A | |||||
Operating Pressure | N/A 232 psi | N/A | N/A | N/A | N/A | |||||
Special Version Operating Pressure1 | N/A 580 psi | N/A | N/A | N/A | N/A | |||||
Direct Current (DC) Supply Voltage | N/A 18 to 36 V | N/A | N/A | N/A | N/A | |||||
Power Supply | N/A 5 W | N/A | N/A | N/A | N/A | |||||
Approval | N/A ATEX II 2G Ex db IIC T4 Gb ATEX II 2D Ex tb IIIC T90 ºC Db DVGW | N/A | N/A | N/A | N/A | |||||
Advantages of Optical Keys | N/A The sensor can also be configured in the ATEX area, without the housing needing to be opened. | N/A | N/A | N/A | N/A | |||||
Special Measurement Technology Features |
N/A
|
N/A | N/A | N/A | N/A | |||||
Special Mechanical Features |
N/A
|
N/A | N/A | N/A | N/A | |||||
Connection to Different Bus Systems Options |
N/A
There are different options available for connection to modern Bus systems:
|
N/A | N/A | N/A | N/A | |||||
Additional Information |
N/A
Easy mounting/dismounting of VA 550 under pressure - without disconnection of the line - without emptying the line If there is no suitable measuring site with 1/2" ball valve, there are two simple possibilities to set up a measuring site: A Weld on a 1/2" screw neck and screw on a 1/2" ball valve B Mount spot drilling collar including ball valve By means of the drilling jig, it is possible to drill under pressure through the 1/2" ball valve into the existing pipe. The drilling chips are collected in a filter. Then the probe can be mounted. |