VD 500 Flow Sensor for Wet Compressed Air

VD 500 Flow Sensor for Wet Compressed Air
Web Price QUOTE

VA 520 Inline Flowmeters

International Organization for Standardization (ISO) Calibration Certificate
Web Price QUOTE

Image

High-Pressure Protection
Web Price QUOTE
Description N/A For measuring immediately downstream of the compressor in moist air up to 356 ºF N/A ISO Calibration Certificate (5 Calibration Points) for VA sensors N/A
Approve Payments N/A Finance with Approve Payments

Measuring Range (Compressed Air) N/A 6.56 to 735 ft/s N/A N/A
Differential Pressure for Gases N/A 0.04 to 500 mbar N/A N/A
Measured Medium N/A Air Non-Aggressive Gases N/A N/A
Accuracy N/A ± 1.5% of Measured Value (M.V.) N/A N/A
Measuring Principle N/A 1:100 N/A N/A
Measuring Span N/A t 99: < 1 sec. N/A N/A
Temperature of The Medium N/A -22 to 356 ºF N/A N/A
Operating Pressure N/A -14.5 to +435.1 psig N/A N/A
Ambient Temperature N/A -4 to +158 ºF N/A N/A
Direct Current (DC) Voltage N/A 18 to 36 V N/A N/A
Power N/A 5 W N/A N/A
Outputs N/A As standard: RS 485 (Modbus-RTU), 4…20 mA, pulse N/A N/A
Optional Output N/A Ethernet Interface M-Bus Power over Ethernet (PoE) N/A N/A
Benefits N/A Benefits at a glance:
  • New: Unique sensitivity in the lower measuring range: Measures from as little as 6.56 f/s and thus covers the complete operating range of variable speed drive (VSD) compressors
  • Particularly suitable for extremely high flow rates
  • Flow, total consumption, temperature and pressure
  • Measurement at high temperatures, max. temperature 356 ºF
  • Can be used in pipes from 3/4" to 24"
  • Installation via 1/2" ball valve under pressure
N/A N/A
Field of Application N/A
  • Measurement immediately downstream of the compressor
  • Measurement at high temperatures
N/A N/A
Typical Applications N/A
  • Measurement of the capacity of compressors
  • Compressed air audits
  • Efficiency measurement of compressed air systems
N/A N/A
Installation Requirements N/A
  • After functioning water separator
  • In horizontal lines (recommended) or in risers
N/A N/A
Additional Information N/A The integrated, precise differential pressure sensor measures the differential pressure/ dynamic pressure at the sensor tip. The pressure depends on the respective gas velocity.

The flow is therefore easy to determine by means of the pipe diameter.

The additional measurement of temperature and absolute pressure and calculation of the relevant density means that measuring can be carried out for various gases, a wide variety of temperatures and pressures.
N/A N/A