Oil Check 400 Monitoring Systems
Compressed Air Quality
Unit of Measure
Items |
![]() 0699 0070 Oil Check 400 Monitoring System Web Price QUOTE
|
![]() 0699 3910 Replacement Unit Oil Check for The Period of Re-Calibration Web Price QUOTE
|
![]() 0699 3920 Replacement Unit Oil Check for The Period of Re-Calibration with DS 400 Web Price QUOTE
|
![]() 0699 3401 Re-Calibration Oil Check 400 with Certificate Web Price QUOTE
|
![]() 0699 3402 Re-Calibration and Maintenance Oil Check 400 with Certificate Web Price QUOTE
|
|||||
Description |
N/A
The monitoring system for permanent highly precise measurement of the vaporous residual oil content in compressed air Oil Check 400 - Residual oil measurement of the vaporous residual oil content from 0.001 to 2.5 mg/m³, 3 to 16 bar. Highly precise PID sensor, integrated mini catalyst for zero point calibration, without integrated display, with analogue output 0 to 10 volts for connection to external chart recorders |
N/A | N/A | N/A | N/A Re-calibration and maintenance Oil Check 400 incl. certificate, rate 1 for up to 8760 operating hours | |||||
Approve Payments |
N/A
Finance with Approve Payments |
|||||||||
Measured Medium | N/A Acid Compressed Air Corrosive Flammable and Oxidizing Components Free From Aggressive Toxic | N/A | N/A | N/A | N/A | |||||
Measuring Unit | N/A Residual oil content in mg oil/norm m³ referred to 14.5 psi [abs], +68 F, 0% relative humidity, in accordance with ISO 8573-1 | N/A | N/A | N/A | N/A | |||||
Identifiable Substances | N/A Aromatic Hydrocarbons Functional Hydrocarbons Hydrocarbons | N/A | N/A | N/A | N/A | |||||
Field of Application | N/A After activated carbon filter, after activated carbon adsorber, after oil-free compressor, always with connected upstream filtration and dryer | N/A | N/A | N/A | N/A | |||||
Operating Time | N/A | N/A | N/A | N/A | N/A 8760 hours | |||||
Ambient Temperature | N/A +5 to 45 ºC | N/A | N/A | N/A | N/A | |||||
Relative Humidity without Condensation | N/A ≤ 75 % | N/A | N/A | N/A | N/A | |||||
Maximum Pressure Dew Point | N/A 10 ºC | N/A | N/A | N/A | N/A | |||||
Compressed Air Temperature | N/A +5 to +50 ºF | N/A | N/A | N/A | N/A | |||||
Operational Overpressure1 | N/A 3 to 16 psi | N/A | N/A | N/A | N/A | |||||
Setting Operational Pressure | N/A By means of integrated pressure reducer with display | N/A | N/A | N/A | N/A | |||||
Humidity of Measured Gas | N/A ≤ 40% relative humidity, pressure dew point maximum +10 ºC, non-condensable humidity | N/A | N/A | N/A | N/A | |||||
Compressed Air Connection | N/A G-1/8 in. Female Thread According to International Organization for Standardization (ISO) 228-1 | N/A | N/A | N/A | N/A | |||||
Measured Values | N/A mg/norm m³, pressure and temperature compensated residual oil vapor content | N/A | N/A | N/A | N/A | |||||
Measuring Range | N/A 0.001 to 2.5 mg/m³ | N/A | N/A | N/A | N/A | |||||
Detection limit (Residual Oil) | N/A 0.001 mg/m³ | N/A | N/A | N/A | N/A | |||||
Approximate Flow of Measuring Gas | N/A 1.20 L/min | N/A | N/A | N/A | N/A | |||||
Note for Approximate Flow of Measuring Gas | N/A Relative to 1.0 bar [abs] and + 20 °C, in a relaxed state | N/A | N/A | N/A | N/A | |||||
Reference Gas Generation | N/A By means of integrated mini catalyst | N/A | N/A | N/A | N/A | |||||
Alternating Current (AC) Voltage | N/A 100 to 240 V | N/A | N/A | N/A | N/A | |||||
Phase | N/A 1 | N/A | N/A | N/A | N/A | |||||
Grounding | N/A Protective Earth (PE) | N/A | N/A | N/A | N/A | |||||
Frequency | N/A 50 to 60 Hz | N/A | N/A | N/A | N/A | |||||
Voltage Tolerance | N/A ±10 % | N/A | N/A | N/A | N/A | |||||
Outputs | N/A 2 Alarm Relays (change 230 VAC 3A) 4…20 mA (on request) Ethernet Interface (Modbus/TCP) RS 485 Interface (Modbus-RTU) | N/A | N/A | N/A | N/A | |||||
Operating Hours Counter | N/A Integrated | N/A | N/A | N/A | N/A | |||||
Width | N/A 410 mm | N/A | N/A | N/A | N/A | |||||
Height | N/A 440 mm | N/A | N/A | N/A | N/A | |||||
Depth | N/A 163 mm | N/A | N/A | N/A | N/A | |||||
Approximate Weight | N/A 16.3 kg | N/A | N/A | N/A | N/A | |||||
Advantages |
N/A
Advantages at a glance:
|
N/A | N/A | N/A | N/A | |||||
Integrated Chart Recorder DS 400 |
N/A
|
N/A | N/A | N/A | N/A | |||||
Options |
N/A
0554 8040, CS Basic - data evaluation in graphic and table form - readout of the measured data via USB or Ethernet. License for 2 working places Z500 4001, 2 additional sensor inputs for analogue sensors (pressure sensors, temperature sensors etc.) Z500 4002, Integrated data logger for 100 million measured values Z500 4004, Integrated Ethernet and RS 485 interface Z500 4005, Integrated webserver Z699 0071, Option: DS 400 chart recorder integrated into Oil Check 400 Z699 0074, Portable sampling system consisting of 2 m PTFE hose, quick coupling (oil- and grease-free) Z699 0075, Sampling system Oil Check 400: Sampling system consisting of 1/2" ball valve (oil- and grease free), 1 m stainless steel tube 6x1 mm (oil- and grease-free), clamp screwing (oil- and grease-free) Z699 0076, For systems > 16 bar: Pressure reducer (oil- and grease-free), input pressure max. 300 bar, output pressure up to 10 bar |
N/A | N/A | N/A | N/A | |||||
|