Laboratory Dry Claw Open Vacuum Systems
Medical, Laboratory and Industrial Vacuum Pump Systems
- Vacuum systems customized specifically for Laboratory Applications
- Packages that leverage proven Dry Claw and Oil Sealed Rotary Vane Technologies
- Easy to use product guide with control panel options and product specification charts to help you find just the right product
Unit of Measure
Items |
/Asset/CVTD-HMI-5-570x570_2.jpg LCPD1005 Laboratory Dry Claw Duplex Tank Mounted Vertical Vacuum System with Premium Controls |
/Asset/CVTD-HMI-5-570x570_2.jpg LCPD1505 Laboratory Dry Claw Duplex Tank Mounted Vertical Vacuum System with Premium Controls |
/Asset/CVTD-HMI-5-570x570_2.jpg LCPT0505 Laboratory Dry Claw Triplex Tank Mounted Vertical Vacuum System with Premium Controls |
/Asset/CVTD-HMI-5-570x570_2.jpg LCPT0605 Laboratory Dry Claw Triplex Tank Mounted Vertical Vacuum System with Premium Controls |
/Asset/CVTD-HMI-5-570x570_2.jpg LCPT0705 Laboratory Dry Claw Triplex Tank Mounted Vertical Vacuum System with Premium Controls |
|||||
Dimension A | N/A 66 in | N/A 90 in | N/A 66 in | N/A 66 in | N/A 66 in | |||||
Dimension B | N/A 59 in | N/A 75 in | N/A 59 in | N/A 59 in | N/A 59 in | |||||
Dimension C | N/A 83 in | N/A 89 in | N/A 85 in | N/A 85 in | N/A 88 in | |||||
Inlet Size | N/A 3 in | N/A 4 in | N/A 3 in | N/A 3 in | N/A 3 in | |||||
Outlet Size (X2) | N/A 2 in | N/A 3 in | N/A | N/A | N/A | |||||
Outlet Size | N/A | |||||||||
Outlet Size (X3) | N/A | N/A | N/A 1 in | N/A 1 in | N/A 1 in | |||||
Outlet Size (X4) | N/A | |||||||||
Air Flow at 19 inHg | N/A 174 scfm | N/A 258 scfm | N/A 87 scfm | N/A 114 scfm | N/A 156 scfm | |||||
Old Pump Power | N/A 8.7 hp | N/A 15 hp | N/A 5 hp | N/A 5.4 hp | N/A 6.4 hp | |||||
New Pump Power | N/A 10 hp | N/A 15 hp | N/A 5 hp | N/A 6.4 hp | N/A 7.0 hp | |||||
Tank Capacity | N/A 200 gal | |||||||||
Tank Orientation | N/A Vertical | |||||||||
Capacity | N/A 43350 Btu/hr | N/A 60690 Btu/hr | N/A 26010 Btu/hr | N/A 33813 Btu/hr | N/A 37716 Btu/hr | |||||
Noise Level | N/A 86 dBA | N/A 88 dBA | N/A 84 dBA | N/A 84 dBA | N/A 84 dBA | |||||
System Full Load Current (F.L.A) at 208 V | N/A 54.8 A | N/A 82 A | N/A 39.8 A | N/A 39.8 A | N/A 59 A | |||||
System Full Load Current (F.L.A) at 230 V | N/A 49.6 A | N/A 72 A | N/A 38 A | N/A 50.6 A | N/A 55.1 A | |||||
System Full Load Current (F.L.A) at 460 V | N/A 25.8 A | N/A 37 A | N/A 20 A | N/A 26.3 A | N/A 28.3 A | |||||
System Weight | N/A 3100 lb | N/A 3400 lb | N/A 3050 lb | N/A 3,200 lb | N/A 3650 lb | |||||
Brands | N/A Powerex® | |||||||||
Type | N/A Duplex | N/A Duplex | N/A Triplex | N/A Triplex | N/A Triplex | |||||
Warranty (Limited) | N/A 3 years | |||||||||
Electrical Panel Opening | N/A 42 in | |||||||||
Minimum Clearance for Ease of Maintenance | N/A 24 in | |||||||||
Motor Voltage | N/A 208 to 230 V460 V | |||||||||
Phase | N/A 3 | |||||||||
Power Supply Frequency | N/A 60 Hz | |||||||||
Panel Screen Size | N/A 6 in | |||||||||
Innovative Technology | N/A Laboratory Dry Claw Tank Mount Systems (with HMI, PBMI or Basic controls) | |||||||||
Control Panel Protection | N/A NEMA 12 NFPA 99 | |||||||||
Industry Standards/Certifications | N/A ASME ISO 9001 UL | |||||||||
General |
N/A
The Powerex® laboratory vacuum system is designed to create a suction system to remove unwanted fluids or gases from laboratory working areas. The laboratory vacuum system package is compliant with the NFPA 99 requirements for Risk Category 3 laboratory systems. Each system is completely tested before shipment and includes:
|
|||||||||
Claw Vacuum Pump |
N/A
Each pump shall be a rotary claw type vacuum pump, and shall be direct-driven through a shaft coupling by a C-face, TEFC electric motor.
|
|||||||||
Motor | N/A The motor is continuous duty, C-face, TEFC, suitable for 208-230, or 460 V, 3 phase, 60 hertz electrical operation. | |||||||||
Air Receiver | N/A The system shall include an ASME rated air receiver. The tank shall be internally lined and come with a manual drain and sight gauge. Systems with Basic Controls are also equipped with a vacuum gauge. Receiver is plumbed so that system vacuum must pass through the air receiver prior to the pumps to provide additional protection for the pumps. | |||||||||
Premium NFPA Control Panel |
N/A
The control system provides automatic lead/lag sequencing and automatic alternation of all pumps in order to equalize the amount of usage among the available vacuum pumps. The Premium NFPA Control Panel shall include a gateway server card and all features listed below:
|
|||||||||
Optional Auto Purge Controls |
N/A
Optional Auto Purge
Note: This option is available with our Premium NFPA Control Panel. It is not available on systems with Basic NFPA controls. Systems with the auto purge feature will include:
|
|||||||||
Service |
N/A
Powerex® has an extensive network of trained sales and service dealers - over 220 authorized service centers throughout the United States, Canada, the Middle East, Central and South Americas. In order to maintain a high level of service, we offer our distributors the chance to participate in our in-house training sessions to be up-to-date on our product offerings, installation and start-up procedures and troubleshooting solutions. |
|||||||||
Engineering |
N/A
Due to our vertical integration and full in-house engineering staff, Powerex® has the ability to customize both electrical control panels as well as the mechanical portion of the system to meet a wide variety of customer needs. Thanks to our continuous process improvement policy and how easily our Sales, Customer Service, Engineering and Production teams can communicate with each other and our end customers, we are constantly figuring out ways to improve our current products and add new products to our standard offerings. |
|||||||||
Innovation |
N/A
Powerex® was the first company to package NFPA 99 compliant scroll systems. Today, we design and manufacture multiple NFPA 99 compliant product lines - Vacuum, Air, and Instrument Air. We were the first company to utilize composite piston technology, now standard on all Powerex® reciprocating compressors. Powerex® also introduced the first dry scroll to the US oil-less compressor market in 1989. The scroll pump’s completely dry compressor chamber along with the low noise and minimal vibration is perfect for applications or locations not considered with reciprocating compressors. |
|||||||||
Quality |
N/A
Powerex® is a highly integrated operation where we not only assemble systems, but we also manufacture many of the major components. From compressors, UL control panels, desiccant dryers, monitors to air receivers, we control quality at every stage of design and manufacturing. All of our facilities are ISO 9001 certified. Unlike our competition, we have used the same compressor brand for decades and also retain the same company ownership since our inception. This allows us to maintain quality and provide consistency in our product offerings year after year. |
|||||||||
The Latest Innovation from Powerex® Laboratory Vacuum Systems |
N/A
|
|||||||||
Laboratory Vacuum System Design |
N/A
|
|||||||||
Control Panel Options | N/A Powerex® offers three different control panel options for our Laboratory Vacuum Systems - HMI controls as our standard and optional PBMI or Basic controls. | |||||||||
Standard HMI Control Panel |
N/A
|
|||||||||
Optional PBMI Control Panel |
N/A
|
|||||||||
Optional Basic Control Panel |
N/A
|
|||||||||
Features |
N/A
|
|||||||||
Available Options |
N/A
|
|||||||||
How It Works | N/A Inside the pump housing, two claw shaped rotors take in air as they rotate in opposite directions. The air is compressed by the rotors, then discharged through a silencer to atmosphere. The pumping chamber is dry. There is no contact between the rotors or the cylinder wall eliminating internal wear and parts to replace. The rotors are synchronized by gears requiring a small amount of oil in the gear housing. Gear oil change requirements are minimal at approximately 20,000 hours. | |||||||||
Note |
N/A
This option is available for systems with Standard HMI controls or Optional PBMI controls. It is not available on systems with Basic controls. Please specify which (air or electric) auto purge option you would like when ordering. For Air Flow at 19 inHg, Compressor Capacity, System Full Load Current (F.L.A) at 208 V, System Full Load Current (F.L.A) at 230 V, System Full Load Current (F.L.A) at 460 V - scfm, Btu and FLA values listed are with all pumps running. |
|||||||||
|