MedAir 2200 is a compact, easy to install and operate compressed airline monitor that can continuously and simultaneously monitor up to four gases in real-time using internally mounted sensors. MedAir 2200 is typically configured to monitor hospital compressed air for carbon monoxide, oxygen and dew point. Four versions available CO Monitor, CO and Oxygen Monitor, CO and Dew Point, and CO, Oxygen and Dew Point.
Product Highlights
Range (CO) |
N/A 0 - 50 ppm |
Accuracy |
N/A 0-30 %. |
Alarm Level Setting |
N/A 10 and 20 ppm CO Alarm 1: +35°F Dew Point Alarm 2: +50°F Dew Point |
Audible Alarm |
N/A 95 dB at 24 in |
Inlet Size |
N/A 1/4" NPT Female |
Power Requirements |
N/A 100 to 240 VAC and/or 12 VDC, 15W |
Weight |
N/A 8 lbs |
General Description |
N/A
Display: High-contrast, backlit
Alarms: Visual: LEDs
Audible: Piezoelectric horn, 95 dB at 2 feet
Alarm Relays: 5 programmable gas relays plus fault. All relays are programmable latching or nonlatching, dry SPDT, 10 amps (resistive load only) at 110 VAC
Operating Power: 100 to 240 VAC and/or 12 VDC, 15 Watts
Sensor Types: CO and O2: Electrochemical, Dew Point: Thin-Film Polymer
Sensor Life: CO: 1-3 years, with calibration, O2: 1-2 years, with calibration, Dew Point: 2 years, replacement
Response Times: Dew point: T90 = 10 seconds for -40° to 50°F step change, CO: T90 = 30 seconds, O2: T90 = 15 seconds
Inlet Pressure: Must be regulated to 55 psi (user provided)
Flow Rate: 1/2 liter per minute (1 SCFH)
Enclosure: Thermoplastic box with clear, hinged front cover, designed for NEMA 12 and 4X
Dimensions: 9.3 W x 11.9 H x 6.1 D inches (21.3 W x 30.3 H x 15.4 D cm)
Weight: 8 lbs. (3.6 kg)
Approvals: UL 60601-1, IEC 60601-1 & CSA 22.2, No. 601.1
STANDARD CALIBRATIONS
Range: 0-50 ppm CO, 0-30% O2 Deficiency, 0-30% O2 Abundance, -112° to +68°F Dew Point(-80° to +20°C)
Alarm Points: 10 and 20 ppm CO, 19.5% O2 Deficiency, 23.5% O2 Abundance, Alarm 1: +35°F Dew Point (+1.6° C), Alarm 2: +50°F Dew Point (+10° C) X Display: High-contrast, backlit
Alarms: Visual: LEDs
Audible: Piezoelectric horn, 95 dB at 2 feet
Alarm Relays: 5 programmable gas relays plus fault. All relays are programmable latching or nonlatching, dry SPDT, 10 amps (resistive load only) at 110 VAC
Operating Power: 100 to 240 VAC and/or 12 VDC, 15 Watts
Sensor Types: CO and O2: Electrochemical, Dew Point: Thin-Film Polymer
Sensor Life: CO: 1-3 years, with calibration, O2: 1-2 years, with calibration, Dew Point: 2 years, replacement
Response Times: Dew point: T90 = 10 seconds for -40° to 50°F step change, CO: T90 = 30 seconds, O2: T90 = 15 seconds
Inlet Pressure: Must be regulated to 55 psi (user provided)
Flow Rate: 1/2 liter per minute (1 SCFH)
Enclosure: Thermoplastic box with clear, hinged front cover, designed for NEMA 12 and 4X
Dimensions: 9.3 W x 11.9 H x 6.1 D inches (21.3 W x 30.3 H x 15.4 D cm)
Weight: 8 lbs. (3.6 kg)
Approvals: UL 60601-1, IEC 60601-1 & CSA 22.2, No. 601.1
STANDARD CALIBRATIONS
Range: 0-50 ppm CO, 0-30% O2 Deficiency, 0-30% O2 Abundance, -112° to +68°F Dew Point(-80° to +20°C)
Alarm Points: 10 and 20 ppm CO, 19.5% O2 Deficiency, 23.5% O2 Abundance, Alarm 1: +35°F Dew Point (+1.6° C), Alarm 2: +50°F Dew Point (+10° C) |