Compressed Air Systems, Inc.
9303 Stannum St
Tampa, FL, 33619-2658, US
Phone: (800) 626-8177
Fax: 813-628-0187
Email: [email protected]
Website: http://www.CompressedAirSystems.com
|

|
|
|
Item # 0695 0573, VA 570 Flowmeter with Integrated 1-1/4 Inch (In) Measuring Section
|
Web Price QUOTE
|
|
|
VA 570 is supplied with an integrated measuring section. The measuring sections are available in flanged version or with R resp. NPT thread.
A special feature is the removable measuring head. So the measuring unit can be removed easily and quickly for calibration or cleaning purposes without having to dismount the measuring section intricately. During this period the measuring section is sealed by a closing cap (accessory).
|
|
|
|
|
|
|
|
|
|
|
|
Measuring Range
|
|
Up to 164 ft/s, Low-Speed Version Up to 304 ft/s, Standard Version Up to 607 ft/s, Maximum Version Up to 735 ft/s, High-Speed Version
|
|
Note for Measuring Range
|
|
All measured values related to DIN 1343 standard conditions 32 ºF and 14.7 psi ex works.
|
|
Accuracy
|
|
± 0.3% of Full Scale (F.S.) ± 1.5% of Measured Value (M.V.)
|
|
Accuracy on Request
|
|
± 1.0% of Measured Value (M.V.) ± 0.3% of Full Scale (F.S.)
|
|
Accuracy Indications
|
|
Relative to Ambient Temperature 71.6 ºF +2 ºF, System Pressure 6 bar
|
|
Repeatability
|
|
0.25% of Measured Value (M.V.) in Case of Correct Mounting (Mounting Aid, Position, Inlet Section)
|
|
Measuring Principle
|
|
Thermal Mass Flow Sensor
|
|
Response Time
|
|
t 90 <3 sec
|
|
Operating/Ambient Temperature Range
|
|
-4 to 158 ºF
|
|
Media Temperature Range
|
|
-4 to 356 ºF
|
|
Media Temperature Range (ATEX Version)
|
|
-4 to 248 ºF
|
|
Adjustment Possibilities via Display, External Hand- Held Device PI 500, PC Service Software, Remote Diagnosis
|
|
Nm³/h, Nm³/min, Nl/min, l/s, ft/min, cfm, kg/h, kg/min, inner diameter, reference conditions ºC/ºF, mbar/hPa, zero point correction, leak flow volume suppression, scaling analog output 4...20 mA, pulse/alarm, error codes etc.
|
|
Standard Outputs
|
|
1 x 4 to 20 mA Analog Output (Electrically Not Isolated) Pulse Output RS 485 (Modbus-RTU)
|
|
Optional Outputs
|
|
2 x 4 to 20 mA Active HART M-Bus Mod- bus TCP Profibus DP Profinet
|
|
Burden
|
|
<500 Ω
|
|
Additional Average Value Calculation
|
|
For all parameters freely adjustable from 1 minute up to 1 day, e. g. 1/2 hours average value, average day value
|
|
Protection Class
|
|
Ingress Protection (IP 64) for ATEX II 2D Ex tb IIIC T90°C Db Ingress Protection (IP 67)
|
|
Housing Material
|
|
Die-Cast Aluminum
|
|
Sensor Tube Material
|
|
Stainless Steel 1.4404
|
|
Operating Pressure
|
|
232 psi
|
|
Special Version Operating Pressure
|
|
580 psi
|
|
Direct Current (DC) Supply Voltage
|
|
18 to 36 V
|
|
Power Supply
|
|
5 W
|
|
Approval
|
|
ATEX II 2G Ex db IIC T4 Gb ATEX II 2D Ex tb IIIC T90 ºC Db DVGW
|
|
|
|
|
|
|
|
|
There are different options available for connection to modern Bus systems:- Ethernet interface (Modbus-TCP) / PoE
- M-BUS
- Modbus-RTU
- Profibus DP interface (in process)
- Profinet interface (in process)
- HART (in process)
|
|
|
|
- 4 values on the display: Flow, total consumption, velocity, temperature. Units freely adjustable
- All measured values, settings such as gas type, inner diameter, serial number and so on can be accessed via Modbus-RTU
- Comprehensive diagnostic functions readable on the display or remote access via Modbus such as calibration cycle, error codes, serial number
- Notification in case of exceeding the calibration cycle
- Standard version accuracy 1.5% of m.v. ± 0.3% of f.s.
- Precision version accuracy 1.0% of m.v. ± 0.3% of f.s
- Measuring span of 1 : 1000 (0.33 ft/s up to 735 ft/s)
- Configuration and diagnosis via display, hand-held device PI 500, PC service software on-site
- Gas type (air, nitrogen, oxygen, argon and so on) freely adjustable via PC service software or external device DS 400, DS 500, PI 500
- Reference conditions ºC and PST / hPA freely adjustable
- In-Situ adjustment, leak flow volume suppression
- Pressure loss negligible
|
|
|
|
- Robust impact-proof aluminum die cast housing for the outdoor area IP 67
- All wetted parts made from stainless steel 1.4404
- On request with DVGW approval for natural gas (up to 232 psi)
- Pressure range up to 232 psi, special version up to 580 psi
- Media temperature range up to 356 ºF (ATEX version up to 248 ºF)
- No moveable parts, no wear
- Sensor tip very robust, easy to clean
- Housing rotatable, display rotatable by -356 ºF
|
|
|
|
The screwing with a centring device is designed such that the sensor is positioned accurately in the center when screwing it into the measuring section; furthermore, it enables an exact positioning in the flow direction. This eliminates unnecessary measuring faults.
|
|
|
|
|
|
|
|
 |
|
|
|
|
|