Parameters
|
|
m³/h, CFM (1000 mbar, 20 ºC) in case of compressed air or Nm³/h, Nl/min (1013 mbar, 0 ºC) in case of gases
|
|
Units Adjustable Via Keys at Display
|
|
CFM ft/min g/s kg/h kg/min l/s lb/h lb/min m/s m³/h m³/min
|
|
Sensor
|
|
Thermal Mass Flow Sensor
|
|
Measured Medium
|
|
Air Gases
|
|
Gas Types are Adjustable Over CS Service Software or CS Data Logger
|
|
Air Argon CO2 Nitrogen Oxygen
|
|
Accuracy
|
|
± 0.3% of Full Scale (F.S.) ± 1.5% of Measured Value (M.V.)
|
|
Accuracy on Request
|
|
± 1.0% of Measured Value (M.V.) ± 0.3% of Full Scale (F.S.)
|
|
Operating Temperature
|
|
-22 to 176 ºF
|
|
Operating Temperature with Pressure Sensor
|
|
-25 to 349 ºF
|
|
Operating Pressure
|
|
-1 to 232 psi
|
|
Optional Pressure
|
|
Up to Nominal Pressure (PN) 40
|
|
Digital Output
|
|
M-Bus Modbus-Remote Terminal Unit (RTU) Optional: Ethernet Interface (PoE) RS 485 Interface
|
|
Analog Output for Cubic Feet Per Minute (CFM)
|
|
4 to 20 mA
|
|
Pulse Output
|
|
1 pulse per CF or per liter electrically isolated. Pulse weight can be set on the display. Alternatively, the pulse output can be used as an alarm relay.
|
|
Direct Current (DC) Supply Voltage
|
|
18 to 36 V
|
|
Power Supply
|
|
5 W
|
|
Burden
|
|
<500 Ω
|
|
Housing Material
|
|
Polycarbonate
|
|
Protection Rating
|
|
Ingress Protection (IP 65)
|
|
Material
|
|
Stainless Steel 1.4301
|
|
Mounting Position
|
|
Any
|
|