Item # 73460, KMM 7-8 Model 41 Inch (in) Length Membrane Dryer for Compressed Air
|
Web Price QUOTE
|
|
|
Innovative, compact dryers for superior efficiency and reliability
The Kaeser Modular Membrane Dryer (KMM) produces pressure dew points to -40ºF. It is perfect for small to medium compressed air systems. KMMs do not require electricity or cooling water, which simplifies installation even in existing systems. They are particularly effective in reaching low pressure dew points when used with a refrigerated dryer and installed at the point of use.
|
|
|
|
|
|
Brands
|
|
Kaeser Compressors
|
|
Model
|
|
KMM 7-8
|
|
Inlet/Outlet Connection Size
|
|
1 in
|
|
Inlet/Outlet Connections Type
|
|
National Pipe Thread (NPT)
|
|
Weight
|
|
40 lb
|
|
Inlet Temperature
|
|
40 ºF 60 ºF 100 ºF
|
|
Outlet Dew Point
|
|
20 ºF -20 ºF 40 ºF -40 ºF
|
|
Inlet Rated Flow Capacity at 100 Pound Per Square Inch Gauge (psig) Pressure, 40 ºF Inlet Temperature, and -20 ºF Outlet Dew Point
|
|
48.6 scfm
|
|
Inlet Rated Flow Capacity at 100 Pound Per Square Inch Gauge (psig) Pressure, 40 ºF Inlet Temperature, and -40 ºF Outlet Dew Point
|
|
33.7 scfm
|
|
Outlet Rated Flow Capacity at 100 Pound Per Square Inch Gauge (psig) Pressure, 40 ºF Inlet Temperature, and -20 ºF Outlet Dew Point
|
|
39.0 scfm
|
|
Outlet Rated Flow Capacity at 100 Pound Per Square Inch Gauge (psig) Pressure, 40 ºF Inlet Temperature, and -40 ºF Outlet Dew Point
|
|
24.1 scfm
|
|
Inlet Rated Flow Capacity at 100 Pound Per Square Inch Gauge (psig) Pressure, 60 ºF Inlet Temperature, and 20 ºF Outlet Dew Point
|
|
79.2 scfm
|
|
Inlet Rated Flow Capacity at 100 Pound Per Square Inch Gauge (psig) Pressure, 60 ºF Inlet Temperature, and -20 ºF Outlet Dew Point
|
|
38.6 scfm
|
|
Inlet Rated Flow Capacity at 100 Pound Per Square Inch Gauge (psig) Pressure, 60 ºF Inlet Temperature, and -40 ºF Outlet Dew Point
|
|
27.1 scfm
|
|
Outlet Rated Flow Capacity at 100 Pound Per Square Inch Gauge (psig) Pressure, 60 ºF Inlet Temperature, and 20 ºF Outlet Dew Point
|
|
69.6 scfm
|
|
Outlet Rated Flow Capacity at 100 Pound Per Square Inch Gauge (psig) Pressure, 60 ºF Inlet Temperature, and -20 ºF Outlet Dew Point
|
|
29.0 scfm
|
|
Outlet Rated Flow Capacity at 100 Pound Per Square Inch Gauge (psig) Pressure, 60 ºF Inlet Temperature, and -40 ºF Outlet Dew Point
|
|
17.5 scfm
|
|
Inlet Rated Flow Capacity at 100 Pound Per Square Inch Gauge (psig) Pressure, 100 ºF Inlet Temperature, and 40 ºF Outlet Dew Point
|
|
66.6 scfm
|
|
Inlet Rated Flow Capacity at 100 Pound Per Square Inch Gauge (psig) Pressure, 100 ºF Inlet Temperature, and 20 ºF Outlet Dew Point
|
|
49.3 scfm
|
|
Inlet Rated Flow Capacity at 100 Pound Per Square Inch Gauge (psig) Pressure, 100 ºF Inlet Temperature, and -20 ºF Outlet Dew Point
|
|
26.2 scfm
|
|
Inlet Rated Flow Capacity at 100 Pound Per Square Inch Gauge (psig) Pressure, 100 ºF Inlet Temperature, and -40 ºF Outlet Dew Point
|
|
18.5 scfm
|
|
Outlet Rated Flow Capacity at 100 Pound Per Square Inch Gauge (psig) Pressure, 100 ºF Inlet Temperature, and 40 ºF Outlet Dew Point
|
|
57.0 scfm
|
|
Outlet Rated Flow Capacity at 100 Pound Per Square Inch Gauge (psig) Pressure, 100 ºF Inlet Temperature, and 20 ºF Outlet Dew Point
|
|
39.7 scfm
|
|
Outlet Rated Flow Capacity at 100 Pound Per Square Inch Gauge (psig) Pressure, 100 ºF Inlet Temperature, and -20 ºF Outlet Dew Point
|
|
16.6 scfm
|
|
Outlet Rated Flow Capacity at 100 Pound Per Square Inch Gauge (psig) Pressure, 100 ºF Inlet Temperature, and -40 ºF Outlet Dew Point
|
|
8.9 scfm
|
|
Warranty
|
|
3 years
|
|
|
|
|
|
|
|
|
KMM with purge air stop valve for even greater energy savings- KMM membrane module with flow concept and helical fiber structure.
- Solenoid pilot-valve: 230 V, 50 Hz, 240 V, 60 Hz, open when de-energized.
- Configured and pre-assembled for immediate use.
- Outlet silencer also included.
|
|
|
|
Function of the Membrane Dryer Module
|
|
Moist compressed air flows into the module casing, where it comes into contact with the membrane fibers. A minimal amount of this now dry compressed air is used as purge air and is drawn upwards around the fibers and expands to atmospheric pressure. The resulting increase in volume increases the air’s water retention capacity. In combination with the selectivity of the membrane, the differing water content of the purge air flow and the flow of air to be dried (both flowing in opposite directions), allows water molecules - almost exclusively - to diffuse through the fiber wall. There are separate outlets for the dried compressed air and the purge air.
|
|
|
|
|
- Space-saving modular design mates easily to prefilters .
- No after-filter required.
- Inside-to-outside permeation allows tight control of purge flow rate.
- Replaceable membrane bundles combine convenience and simplicity.
- Welded aluminum housings are lightweight and rugged.
- Powder coating inside and out for excellent corrosion resistance
|
|
|
|
- Purge Saver
- Pre-filter packages
- Single pre-filter
- Dual pre-filters
|
|
|
|
Efficiency and Dependability
The KMM dryer provides many advantages over conventional membrane dryer models. The "inflow" design ensures outstanding drying results by effectively removing moisture, enhancing pressure stability and reducing pressure differential. The welded aluminum housing and epoxy powder coating provide durability in harsh environments. Its lightweight design requires no additional support structure, and the space-saving modular design connects easily to prefilters and after filters. In-line filters are recommended with a KMM to prevent contaminants from reaching the sensitive membrane fibers.
|
|
|
|
Use inlet air temperature if the air entering the dryer has not been dried upstream (air is saturated). If air has been dried (e.g. in a refrigerated dryer) use the dew point temperature of the inlet air.
Flow capacities are at 100 psig. Capacities are established in accordance with CAGI Standard ADF 700; Membrane Compressed Air Dryers - Methods for Testing and Rating. Larger capacities, alternate pressures, and dew points consult factory.
Dimensions and weights are for reference only.
Specifications are subject to change without notice.
The standard one year warranty is extended to three years when the dryer is installed with an optional pre-filter package. To keep the warranty in effect, filter elements must be replaced at six month intervals and the drain mechanism yearly.
|
|
|
|
|
|
|
|
 |
|
|
|
|
|