Measurement Range1
|
|
-148 to +68 ºF -100 to +20 ºC 3000 ppmv
|
|
Accuracy
|
|
± 3.6 ºF ± 2 ºC
|
|
Operating Temperature Range
|
|
+23 to +122 ºF -5 to +50 ºC
|
|
Storage Temperature
|
|
-40 to +167 ºF -40 to +75 ºC
|
|
Output Current
|
|
4 to 20 mA
|
|
Maximum Load Resistance
|
|
500 Ω
|
|
Alarm Voltage2
|
|
2 V
|
|
User Interface
|
|
Front Panel Configuration of Alarm Points
|
|
Alternating Current (AC) Voltage
|
|
85 to 265 V
|
|
Power Supply Frequency
|
|
50 Hz 60 Hz
|
|
Ingress Protection
|
|
National Electrical Manufacturers Association (NEMA) 4X Ingress Protection (IP65)
|
|
Power Cord3
|
|
6.5 ft 2 m
|
|
Maximum Pressure4
|
|
145 psig 1 MPa 10 barg
|
|
Sample Flow Rate
|
|
2.1 to 10.5 scfh 1 to 5 L/min
|
|
Filtration5
|
|
99.5 %
|
|
Connection Size6
|
|
6 mm
|
|
Sensor Guard
|
|
Sintered High-Density Polyethylene (HDPE)
|
|
Protective Case
|
|
Polycarbonate
|
|
Internal Tubing
|
|
Polytetrafluoroethylene (PTFE)
|
|
Length
|
|
8.46 in
|
|
Back Length
|
|
5.31 in
|
|
Width
|
|
11.22 in
|
|
Warranty
|
|
1 years
|
|
1 Choice of dew point or ppmv must be specified at time of order. Non standard dew point ranges available on request.
2 Free contacts (3 A at 240 V)
3 Power cord provided
4 Higher pressure options available on request
5 Removal efficiency at 0.3 micron
6 Outer Diameter Quick Connect Tube Fittings
|
|