Compressed Air Systems, Inc.
9303 Stannum St
Tampa, FL, 33619-2658, US
Phone: (800) 626-8177
Fax: 813-628-0187
Email: [email protected]
Website: http://www.CompressedAirSystems.com
All Categories > Clean Air Treatment > Filtration > MST Purification & Filtration > Carbon Monoxide Monitors and Accessories > Carbon Monoxide Monitors / Alarms > Enmet Carbon Monoxide & Oxygen Monitor/Alarms > Item # MedAir 2200  




Item # MedAir 2200, Enmet Compressed Airline Monitor

Web Price QUOTE

MedAir 2200 is a compact, easy to install and operate compressed airline monitor that can continuously and simultaneously monitor up to four gases in real-time using internally mounted sensors. MedAir 2200 is typically configured to monitor hospital compressed air for carbon monoxide, oxygen and dew point. Four versions available CO Monitor, CO and Oxygen Monitor, CO and Dew Point, and CO, Oxygen and Dew Point.





Financing  · Specifications  · Power Requirements  · Dimensions  · General Description  · Additional Information

Financing

Approve Payments

Finance with Approve Payments



Specifications

Range (CO)

0 to 50 ppm

Accuracy

0 to 30 %

Alarm Level Setting

10 and 20 ppm CO
Alarm 1: +35 ºF Dew Point

Alarm 2: +50 ºF Dew Point

Audible Alarm

95 dB at 24 in

Inlet Size

1/4 in. National Pipe Thread (NPT) Female

Weight

8 lb


Power Requirements

Alternating Current (AC) Voltage

100 to 240 V

Direct Current (DC) Voltage

12 V

Power

15 W


Dimensions

Width

9.3 in
21.3
cm

Height

11.9 in
30.3
cm

Depth

6.1 in
15.4
cm


General Description
Display: High-contrast, backlit

Alarms: Visual: LEDs

Audible: Piezoelectric horn, 95 dB at 2 feet

Alarm Relays: 5 programmable gas relays plus fault. All relays are programmable latching or non-latching, dry SPDT, 10 amps (resistive load only) at 110 VAC

Operating Power: 100 to 240 VAC and/or 12 VDC, 15 Watts

Sensor Types: CO and O2: Electrochemical, Dew Point: Thin-Film Polymer

Sensor Life: CO: 1-3 years, with calibration, O2: 1-2 years, with calibration, Dew Point: 2 years, replacement

Response Times: Dew point: T90 = 10 seconds for -40º to 50ºF step change, CO: T90 = 30 seconds, O2: T90 = 15 seconds

Inlet Pressure: Must be regulated to 55 psi (user provided)

Flow Rate: 1/2 liter per minute (1 SCFH)

Enclosure: Thermoplastic box with clear, hinged front cover, designed for NEMA 12 and 4X

Dimensions: 9.3 W x 11.9 H x 6.1 D inches (21.3 W x 30.3 H x 15.4 D cm)

Weight: 8 lbs. (3.6 kg)

Approvals: UL 60601-1, IEC 60601-1 & CSA 22.2, No. 601.1

STANDARD CALIBRATIONS

Range: 0-50 ppm CO, 0-30% O2 Deficiency, 0-30% O2 Abundance, -112º to +68ºF Dew Point(-80º to +20ºC)

Alarm Points: 10 and 20 ppm CO, 19.5% O2 Deficiency, 23.5% O2 Abundance, Alarm 1: +35ºF Dew Point (+1.6º C), Alarm 2: +50ºF Dew Point (+10º C)



Additional Information
Product Highlights
  • Continuous real-time gas monitoring of hospital compressed airlines
  • Monitors oxygen, carbon monoxide and dew point simultaneously
  • User programmable alarms and relays
  • Meets Grade D breathing and NFPA 99 requirements
  • Low flow alarm
  • Field replaceable sensors
Link

ENMET has a complete line of compressed airline monitoring and filtration systems for supplied breathing, respiratory air, process air, and hospital compressed airlines. There continuous in-line carbon monoxide CO monitors and three-stage respiratory airline filtration panels are designed to meet OSHA 1910.134 compressed breathing air monitoring requirements.




Print Back