Compressed Air Systems, Inc.
9303 Stannum St
Tampa, FL, 33619-2658, US
Phone: (800) 626-8177
Fax: 813-628-0187
Email: [email protected]
Website: http://www.CompressedAirSystems.com
All Categories > Clean Air Treatment > Filtration > MST Purification & Filtration > Carbon Monoxide Monitors and Accessories > Carbon Monoxide Monitors / Alarms > Enmet Carbon Monoxide & Oxygen Monitor/Alarms > Item # AM-5175  




Item # AM-5175, Enmet Fixed Gas Detection System

Web Price QUOTE

Enmet Single Point Hazardous Gas Monitor for Ambient Air is available for Carbon Monoxide (CO), Hydrogen Sulfide (H2S), or Oxygen (O2). The AM-5175 provides a digital display of gas concentration, audio/visual alarms, relay contacts, plus analog and digital outputs. The monitor incorporates electrochemical CO, H2S or O2 cells.





Financing  · Specifications  · Power Requirements  · Dimensions  · General Description  · Additional Information

Financing

Approve Payments

Finance with Approve Payments



Specifications

Audible Alarm

105 dB at 12 in

Inlet Size

Supplied with strain relief for 0.20 to 0.35 inch diameter power cable

Operating Temperature Range

32 to 122 ºF

Weight

2 lb


Power Requirements

Alternating Current (AC) Voltage

100 to 240 V

Direct Current (DC) Voltage

24 V

Power

15 W


Dimensions

Width

7 in
18
cm

Height

5 in
13
cm

Depth

3 in
8
cm


General Description
Display:High-contrast dot matrix LCD with backlight

Alarm Levels:Three, user adjustable

Audible Alarm:105 dB at 30 cm (12 inches), factory set to activate at Alarm 1, user adjustable

Visual Gas Alarm:3 Red LEDs

Visual Power/Fault:Green/Red LED

Temp. Range:32° to 122°F (0° to 50°C)

Outputs:Relays:4 Form C, 10A SPDT contacts, 3 gas alarms and 1 fault

Analog:4-20 mA

Digital:RS-485 Modbus

Power:100-240 VAC and/or 24 VDC, 15W. Supplied with strain relief for 0.20 to 0.35 inch diameter power cable

Enclosure:Polycarbonate

Size, Instrument Only:7 x 5 x 3 inches (18 x 13 x 8 cm)

Weight:2 lbs. (0.9 kg)



Additional Information
Product Highlights
  • User-programmable alarms and high capacity relays
  • 4-20 mA inputs
  • 100-240 VAC, 24 VDC power options
  • High-integrity polycarbonate enclosure
  • RS-485 digital communication capability
ENMET has a complete line of compressed airline monitoring and filtration systems for supplied breathing, respiratory air, process air, and hospital compressed airlines. There continuous in-line carbon monoxide CO monitors and three-stage respiratory airline filtration panels are designed to meet OSHA 1910.134 compressed breathing air monitoring requirements.