The Apollo Ambient Air Pump must be placed outside of the blast environment in an area free of airborne contaminants. These potential contaminants include, but are not limited to the following — fumes from paints and solvents, exhausts from vehicles and compressors, smoke from burn barrels, and dust from abrasive blasting or other construction activities.

The ambient air pump moves air from a clean location to supply low-pressure respirators. To increase its effective range, the ambient air pump can be connected to an optional remote inlet kit — which allows the air inlet to be located up to 300 feet from the pump. 

Before blasting begins, and before putting on the respirator, the operator connects the respirator hose to the ambient pump and to the fixed-orifice air inlet at the respirator. The operator starts the compressor, turns on the ambient air pump, adjusts the pressure, and checks for leaks, then puts on the respirator in a clean environment.

After blasting, the operators keep the respirators on and connected until they reach an area free of airborne dust and contamination.

The primary air connection uses a special quick-connect fitting that allows air to flow, even when not connected to a respirator. This keeps hazardous dust or other contaminants from entering the hose at the connection point.

Advantages
• Supplies air for up to four blast operators wearing type CE helmets or up to six operators wearing full face masks
• Eliminates the expense of separate compressor for breathing air
• Uses compressed air for power; works where no electric power is available
• Eliminates danger of carbon monoxide poisoning caused when high temperatures break down compressor’s lubricants
• Requires no temperature alarms or additional air line filters
• Works with Clemco’s CO Monitor Alarm (when specifications call for air monitoring)
• Model CAP-4C includes integral two-wheel cart and extendable handle
• Protective cage (both models) shields critical components from damage
• Easy to operate and maintain
• Can serve as air source for other respirators that operate at 9 cfm at 10 psi

Unit of Measure

Financing

Approve Payments

N/A Finance with Approve Payments

Specifications

Output

N/A 10 psi

Secondary Air Supply Pressure Range

N/A 30-70 cfm / 85 psi min.