The POD-TD removes all types of condensate from compressed air systems up to 100 m³/min. without the requirement of electricity.
The discharge process is automatic and is based on a newly developed 3/2 way level controlled valve principle that operates a piston type direct acting valve.
The POD-TD is ideally suited in applications where power is not available, too expensive or not reliable.
The integrated stainless steel strainer protects the valve, optimizing the discharge performance.
The discharge process is automatic and is based on a newly developed 3/2 way level controlled valve principle that operates a piston type direct acting valve.
The POD-TD is ideally suited in applications where power is not available, too expensive or not reliable.
The integrated stainless steel strainer protects the valve, optimizing the discharge performance.
Unit of Measure
Financing
|
Specifications
|
Technical Specification
|
Commercial Benefits
|
Technical Advantages
|
Note
Specifications
Brands |
N/A Jorc |
Media |
N/A Condensate |
Industry Standards/Certifications |
N/A CE NEN - EN - ISO 9001:2015 Certified |
Technical Specification
Maximum Compressor Capacity |
N/A 100 m³/min |
Maximum Drainage Capacity1 | N/A 1062 L |
Minimum/Maximum System Pressure |
N/A 3 to 16 bar |
Minimum/Maximum Medium Temperature |
N/A 1 to 50 ºC |
Minimum/Maximum Ambient Temperature |
N/A 1 to 50 ºC |
Inlet Connection Size |
N/A 0 1/2 in |
Inlet Connection Type |
N/A British Standard Pipe (BSP) National Pipe Thread (NPT) |
Number of Inlet Options |
N/A 3 |
Top Inlet Height |
N/A 11.2 cm |
Side Inlet Height |
N/A 1.5 cm9.7 cm |
Outlet Connection Size |
N/A 1/4 in |
Outlet Connection Type |
N/A British Standard Pipe (BSP) |
Valve Type |
N/A Direct Acting |
Valve Orifice |
N/A 6 mm |
Valve Seal |
N/A FPM |
Serviceable Valve |
N/A true |
Integrated Mesh Strainer |
N/A true |
Housing Material |
N/A Corrosion Resistant Aluminum Electrophoretic (EP) Coating |
Test Feature |
N/A true |
Environmental Protection Inlet |
N/A Ingress Protection (IP68) (National Electrical Manufacturers Association (NEMA 6)) |
Commercial Benefits
Commercial Benefits |
N/A
|
Technical Advantages
Technical Advantages |
N/A Information provided herewith is believed to be accurate and reliable. However, no responsibility is assumed for its use or for any infringement of patents or rights of others, which may result from its use. In addition, Jorc reserves the right to revise information without notice and without incurring any obligation. |
Note
Note |
N/A Information provided herewith is believed to be accurate and reliable. However, no responsibility is assumed for its use or for any infringement of patents or rights of others, which may result from its use. In addition, Jorc reserves the right to revise information without notice and without incurring any obligation. |
- 1 Condensate Per Hour at 16 bar.