The compressor block is 4 stage, air cooled, pressure lubricated, has inter coolers and after cooler, relief valves on all stages, and a multi-blade flywheel fan to provide high velocity cooling over the compressor. Standard equipment includes an auto-drain system, inner stage gauges, hour meter, high pressure shut down, carbon-monoxide visual indicator and a fully enclosed, sound dampened cabinet with gauge panel.
Unit of Measure

Specifications

Air Flow

N/A 14 cfm

Pressure

N/A 6000 psi

Electric Motor Power

N/A 10 hp

Phase

N/A Three Single

Height

N/A 66 3/4 in

Depth

N/A 23 in

Width

N/A 36 in

Approximate Weight

N/A 600 lb

Stages

N/A Four

Number of Chambers

N/A 1

Air Capacity

N/A 24000 ft³

Dew Point for Dryer

N/A -65 º

Industry Standards/Certifications

N/A CGA NFPA 1500

Electrical Requirements

Minimum Current for Single Phase Operation

N/A 50 A

Minimum Voltage for Single Phase Operation

N/A 230 V

Minimum Current for Three Phase Operation

N/A 40 A

Minimum Voltage for Three Phase Operation

N/A 208 V230 V

Purification

N/A The filtration system consists of one chamber rated at 24,000 cu. ft. of air capacity. The system uses a dryer bed to remove water in excess of dew point - 65 degrees. (NFPA 1500 standard) Activated charcoal and a carbon monoxide catalyst remove remaining contaminants to provide CGA Grade "E" breathing air. Additional filtration capacity can added for high volume users.