• Home
  Products

• Air Compressors
     Used Air Compressors
     Industrial Air Compressors
     Kaeser Compressor
     Rotary Screw Air Compressor
     Portable Air Compressor
     Reciprocating Air Compressor
     Dental Air Compressor
     High Pressure Air Compressor
     Electric Air Compressor
     Gas Air Compressor
     Diesel Air Compressor
     
Oil Less Air Compressors
     Medical Air Compressor
     Remanufactured Compressor 
     EARS North America
     VMAC Underhood Compressor 
     Portable Air Compressor Tanks

• Miscellaneous Equipment
     Industrial Vacuum System
     Sandblast Equipment
     Railcar Door Opener
     P.O.G.O.
     Air Compressor Piping

     Air Compressor Accessories
     Air Compressor Tools
     Air Compressor Fittings
     Air Compressor Parts

     Air Receiver Tanks
     Air Compressor Lubricant
    
Spray Booth
     Refrigerated Air Dryers 
     Solberg Air Cleaners 
     Nitrogen Generators 
     Vacuum and Pressure Gauges 
     Compressed Air Dryers 
     Air Purification Systems      Rotary Vane Vacuum Pumps      Air Blower Options

• Services Department
     Air Compressor Services
     Compressed Air Audits
     Air Compressor Repair
     Air Compressor Rental
     Used Equipment
     Engineering Services
• Air Compressor Information
     When to Buy Used
     Selecting an Air Compressor
     Portable Air Compressors

     Air Compressor Systems
    
Compressed Air Treatment
     Air Compressor Ratings
     Air Compressor Buyers Guide

     Air Compressor Tips and Hints
    
Compressed Air Cost
     Air Compressor Maintenance
     Air Compressor Filtration
     Reconditioned Compressors
     Compressor Manufacturers  
     Preventative Maintenance
     Air Compressor for Industrial      Use
     Air Compressor Filter Oil
     
    

 

 
Search Catalog
      GO   
 All Categories    VA 570 Inline Flowmeters
View Cart View RFQs  | Shipping 
 | Tax 
 | Terms
 Shopping Cart 0 Items
 Request for Quote 0 Items
All Categories > Flow Thermal > VA 570 Inline Flowmeters > Item # 0695 2572  
Add To Cart Request Quote

Item # 0695 2572, VA 570 Flowmeter with Integrated 1 Inch (In) Measuring Section with Flange

Web Price QUOTE

    Download PDF Download PDF   
    border="0" Printable Page  
    Email Email This Page  
    Save To Favorites Save To Favorites
  

VA 570 is supplied with an integrated measuring section. The measuring sections are available in flanged version or with R resp. NPT thread.

A special feature is the removable measuring head. So the measuring unit can be removed easily and quickly for calibration or cleaning purposes without having to dismount the measuring section intricately. During this period the measuring section is sealed by a closing cap (accessory).





Financing  · Specifications  · Measuring Range  · Flange  · Connection to Different Bus Systems Options  · Special Measurement Technology Features  · Special Mechanical Features  · Additional Information

Financing

Approve Payments

Finance with Approve Payments



Specifications

Measuring Range

Up to 164 ft/s, Low-Speed Version
Up to 304 ft/s, Standard Version

Up to 607 ft/s, Maximum Version

Up to 735 ft/s, High-Speed Version

Note for Measuring Range

All measured values related to DIN 1343 standard conditions 32 ºF and 14.7 psi ex works.

Accuracy

± 0.3% of Full Scale (F.S.)
± 1.5% of Measured Value (M.V.)

Accuracy on Request

± 1.0% of Measured Value (M.V.)
± 0.3% of Full Scale (F.S.)

Accuracy Indications

Relative to Ambient Temperature 71.6 ºF +2 ºF, System Pressure 6 bar

Repeatability

0.25% of Measured Value (M.V.) in Case of Correct Mounting (Mounting Aid, Position, Inlet Section)

Measuring Principle

Thermal Mass Flow Sensor

Response Time

t 90 <3 sec

Operating/Ambient Temperature Range

-4 to 158 ºF

Media Temperature Range

-4 to 356 ºF

Media Temperature Range (ATEX Version)

-4 to 248 ºF

Adjustment Possibilities via Display, External Hand- Held Device PI 500, PC Service Software, Remote Diagnosis

Nm³/h, Nm³/min, Nl/min, l/s, ft/min, cfm, kg/h, kg/min, inner diameter, reference conditions ºC/ºF, mbar/hPa, zero point correction, leak flow volume suppression, scaling analog output 4...20 mA, pulse/alarm, error codes etc.

Standard Outputs

1 x 4 to 20 mA Analog Output (Electrically Not Isolated)
Pulse Output

RS 485 (Modbus-RTU)

Optional Outputs

2 x 4 to 20 mA Active
HART

M-Bus

Mod- bus TCP

Profibus DP

Profinet

Burden

<500 Ω

Additional Average Value Calculation

For all parameters freely adjustable from 1 minute up to 1 day, e. g. 1/2 hours average value, average day value

Protection Class

Ingress Protection (IP 64) for ATEX II 2D Ex tb IIIC T90°C Db
Ingress Protection (IP 67)

Housing Material

Die-Cast Aluminum

Sensor Tube Material

Stainless Steel 1.4404

Operating Pressure

232 psi

Special Version Operating Pressure

580 psi

Direct Current (DC) Supply Voltage

18 to 36 V

Power Supply

5 W

Approval

ATEX II 2G Ex db IIC T4 Gb
ATEX II 2D Ex tb IIIC T90 ºC Db

DVGW


Measuring Range

Low-Speed Air Flow (164 Feet Per Seconds (ft/s))

75 L/min
45
ft³/min

Standard Air Flow (304 Feet Per Seconds (ft/s))

145 m³/h
85
ft³/min

Maximum Air Flow (607 Feet Per Seconds (ft/s))

290 m³/h
170
ft³/min

High-Speed Air Flow (735 Feet Per Seconds (ft/s))

355 m³/h
210
ft³/min

Note for Air Flow

Reference conditions DIN 1945 / ISO 1217: 68 ºF, 14 psi

Low-Speed Argon (Ar) Flow (164 Feet Per Seconds (ft/s))

120 L/min
70
ft³/min

Standard Argon (Ar) Flow (304 Feet Per Seconds (ft/s))

230 m³/h
135
ft³/min

Maximum Argon (Ar) Flow (607 Feet Per Seconds (ft/s))

460 m³/h
270
ft³/min

High-Speed Argon (Ar) Flow (735 Feet Per Seconds (ft/s))

555 m³/h
325
ft³/min

Note for Argon (Ar) Flow

Setting to DIN 1343: 32 ºF, 14.7 psi

Low-Speed Carbon Dioxide (CO2) Flow (164 Feet Per Seconds (ft/s))

75 L/min
45
ft³/min

Standard Carbon Dioxide (CO2) Flow (304 Feet Per Seconds (ft/s))

145 m³/h
85
ft³/min

Maximum Carbon Dioxide (CO2) Flow (607 Feet Per Seconds (ft/s))

290 m³/h
170
ft³/min

High-Speed Carbon Dioxide (CO2) Flow (735 Feet Per Seconds (ft/s)

350 m³/h
205
ft³/min

Note for Carbon Dioxide (CO2) Flow

Setting to DIN 1343: 32 ºF, 14.7 psi

Low-Speed Nitrogen (N2) Flow (164 Feet Per Seconds (ft/s))

70 L/min
40
ft³/min

Standard Nitrogen (N2) Flow (304 Feet Per Seconds (ft/s))

135 m³/h
75
ft³/min

Maximum Nitrogen (N2) Flow (607 Feet Per Seconds (ft/s))

270 m³/h
155
ft³/min

High-Speed Nitrogen (N2) Flow (735 Feet Per Seconds (ft/s))

325 m³/h
190
ft³/min

Note for Nitrogen (N2) Flow

Setting to DIN 1343: 32 ºF, 14.7 psi

Low-Speed Oxygen (O2) Flow (164 Feet Per Seconds (ft/s))

75 L/min
40
ft³/min

Standard Oxygen (O2) Flow (304 Feet Per Seconds (ft/s))

140 m³/h
80
ft³/min

Maximum Oxygen (O2) Flow (607 Feet Per Seconds (ft/s))

280 m³/h
165
ft³/min

High-Speed Oxygen (O2) Flow (735 Feet Per Seconds (ft/s))

340 m³/h
200
ft³/min

Note for Oxygen (O2) Flow

Setting to DIN 1343: 32 ºF, 14.7 psi

Low-Speed Nitrous Oxide (N2O) Flow (164 Feet Per Seconds (ft/s))

75 L/min
45
ft³/min

Standard Nitrous Oxide (N2O) Flow (304 Feet Per Seconds (ft/s))

140 m³/h
85
ft³/min

Maximum Nitrous Oxide (N2O) Flow (607 Feet Per Seconds (ft/s))

285 m³/h
170
ft³/min

High-Speed Nitrous Oxide (N2O) Flow (735 Feet Per Seconds (ft/s))

345 m³/h
205
ft³/min

Note for Nitrous Oxide (N2O) Flow

Setting to DIN 1343: 32 ºF, 14.7 psi

Low-Speed Natural Gas (NG) Flow (164 Feet Per Seconds (ft/s))

45 L/min
25
ft³/min

Standard Natural Gas (NG) Flow (304 Feet Per Seconds (ft/s))

85 m³/h
50
ft³/min

Maximum Natural Gas (NG) Flow (607 Feet Per Seconds (ft/s))

170 m³/h
100
ft³/min

High-Speed Natural Gas (NG) Flow (735 Feet Per Seconds (ft/s))

210 m³/h
120
ft³/min

Note for Natural Gas (NG) Flow

Setting to DIN 1343: 32 ºF, 14.7 psi


Flange

Flange Pipe Size

1 in

Flange Outer Pipe Diameter

33.7 mm

Flange Inner Pipe Diameter

27.3 mm

Dimension L (Flange)

18.7 in

Note for Dimension L (Flange)

Attention: Shortened inlet section. Please observe the recommended minimum inlet section (length = 15 x inner diameter) on site.

Dimension L1 (Flange)

10.83 in

Dimension H (Flange)

10.83 in

Dimension H1 (Flange)

8.58 in

Diameter D (Flange)

115 mm

Diameter K (Flange)

85 mm

Number of Diameter L (Flange)

4

Diameter L (Flange)

14 mm


Connection to Different Bus Systems Options
There are different options available for connection to modern Bus systems:
  • Ethernet interface (Modbus-TCP) / PoE
  • M-BUS
  • Modbus-RTU
  • Profibus DP interface (in process)
  • Profinet interface (in process)
  • HART (in process)




Special Measurement Technology Features
  • 4 values on the display: Flow, total consumption, velocity, temperature. Units freely adjustable
  • All measured values, settings such as gas type, inner diameter, serial number and so on can be accessed via Modbus-RTU
  • Comprehensive diagnostic functions readable on the display or remote access via Modbus such as calibration cycle, error codes, serial number
  • Notification in case of exceeding the calibration cycle
  • Standard version accuracy 1.5% of m.v. ± 0.3% of f.s.
  • Precision version accuracy 1.0% of m.v. ± 0.3% of f.s
  • Measuring span of 1 : 1000 (0.33 ft/s up to 735 ft/s)
  • Configuration and diagnosis via display, hand-held device PI 500, PC service software on-site
  • Gas type (air, nitrogen, oxygen, argon and so on) freely adjustable via PC service software or external device DS 400, DS 500, PI 500
  • Reference conditions ºC and PST / hPA freely adjustable
  • In-Situ adjustment, leak flow volume suppression
  • Pressure loss negligible




Special Mechanical Features
  • Robust impact-proof aluminum die cast housing for the outdoor area IP 67
  • All wetted parts made from stainless steel 1.4404
  • On request with DVGW approval for natural gas (up to 232 psi)
  • Pressure range up to 232 psi, special version up to 580 psi
  • Media temperature range up to 356 ºF (ATEX version up to 248 ºF)
  • No moveable parts, no wear
  • Sensor tip very robust, easy to clean
  • Housing rotatable, display rotatable by -356 ºF




Additional Information
The screwing with a centring device is designed such that the sensor is positioned accurately in the center when screwing it into the measuring section; furthermore, it enables an exact positioning in the flow direction. This eliminates unnecessary measuring faults.



 DOWNLOADS 

Datasheet for VA 570 Inline Flowmeters
(PDF, 728KB)


Add To Cart Request Quote