The nano BAC portable breathing air case is the solution for one or multiple users who need a robust, go anywhere breathable air filtration system.

With maximum flow rates of either 50 scfm or 100 scfm, the impact and water resistant case houses a nano F1 NWS water separator, an M01 0.01 micron coalescing filter with automatic condensate drains and an AC activated carbon adsorber to remove moisture, oil aerosols, odors and taste to 0.003 ppm all in one simple, portable package.
Unit of Measure

Financing

Approve Payments

N/A Finance with Approve Payments

Specifications

Shipping Weight

N/A 28 lb

Flow Capacity

N/A 14 to 486 scfm

Operating Pressure Range

N/A 15 to 150 psig

Recommended Operating Temperature Range

N/A 35 to 86 ºF

Warranty

N/A 2 years

Industry Standards/Certifications

N/A CAN3-Z180.1-M85 (Canada) OSHA Grade D (US)

Global Breathing Air Quality Standards

Global Breathing Air Quality Standards

N/A When applied, operated and maintained correctly, the nano range of B1 breathing air cases, panels and purifier systems are guaranteed to meet and exceed global standards for breathing air quality.

Standard (United States)

N/A CGA7.1 OSHA Grade D

Maximum Dew Point (United States)

N/A Varies by Application

Maximum Oil Content (United States)

N/A 5 mg/m³

Odor and Taste (United States)

N/A No Pronounced Odor

Allowable O2 Range (United States)

N/A 19.5 to 23.5 %

Maximum CO Level (United States)

N/A 10 ppm

Maximum CO2 Level (United States)

N/A 1000 ppm

Standard (Canada)

N/A CAN3-Z180.1-M85

Maximum Dew Point (Canada)

N/A 5 ºC Below Lowest System Temperature

Maximum Oil Content (Canada)

N/A 1 mg/m³

Odor and Taste (Canada)

N/A No Pronounced Odor

Allowable O2 Range (Canada)

N/A 20 to 22 %

Maximum CO Level (Canada)

N/A < 5 ppm

Maximum CO2 Level (Canada)

N/A < 600 ppm

Standard (UK and Europe)

N/A EN12021

Maximum Dew Point (UK and Europe)

N/A -23 ºF-31 ºC

Maximum Oil Content (UK and Europe)

N/A 0.01 mg/m³

Odor and Taste (UK and Europe)

N/A No Pronounced Odor

Allowable O2 Range (UK and Europe)

N/A 21 %

Allowable O2 Tolerance (UK and Europe)

N/A ± 1 %

Maximum CO Level (UK and Europe)

N/A < 5 ppm

Maximum CO2 Level (UK and Europe)

N/A < 500 ppm

Inlet Connection

Inlet Connection Size

N/A 0 1/2 in

Inlet Connection Type

N/A National Pipe Thread (NPT (F))

Inlet Connection Quantity

N/A 1

Outlet Connection

Outlet Connection Size

N/A 3/8 in

Outlet Connection Type

N/A National Pipe Thread (NPT (F))

Outlet Connection Quantity

N/A 4

Flow

Inlet Flow

N/A 50 scfm

Outlet Flow

N/A 50 scfm

Dimensions

Height

N/A 17 in

Width

N/A 24 in

Depth

N/A 8.5 in

Portable Breathing Air Cases

N/A All BAC cases include an adjustable pressure regulator and Carbon Monoxide (CO) monitor (does not remove CO, only monitors it) to ensure safe and reliable operation.

  • wall or skid mountable
  • 50, 100 or 175 scfm flow rates available
  • multiple outlet connections for multiple users
  • adjustable pressure regulator
  • integral CO monitor (does not remove CO, only monitors it)
  • complies with OSHA Grade D (US) and CAN3-Z180.1-M85 (Canada) breathing air standards

Modular Breathing Air Purifier Systems

N/A While many breathing air applications may require only the removal of particulate, oil, odor and taste, others may also require the removal of hazardous gases.

Carbon Dioxide (CO2) and Carbon Monoxide (CO) are odorless, tasteless gases that can be harmful or even lethal if inhaled - especially in high concentrations. If there is the potential for high levels of CO or CO2 in the air, it is imperative they are reduced to safe levels for breathing.

These critical applications call for the nano modular NBA breathing air purifier. The NBA purifiers start by filtering the air using an M1 1.0 micron pre-filter and an M01 0.01 micron high-efficiency coalescing pre-filter. However, the NBA then also removes CO and CO2 using a 4-layer, mixed bed cartridge in aluminum extruded vessels.

The new B1 breathing air purifier systems are based on the tested and proven nano D1, D2, and D3 modular dryers but employ a unique split cartridge system to completely treat the air prior to respiration.

The first stage of the cartridge removes water vapor to -40 (does not remove CO, only monitors it) F/C pressure dew point and polishes CO2 using a novel activated alumina and 13X molecular sieve mix. The second stage utilizes activated carbon to remove hydrocarbons, odor and taste. Finally, the last stage of the cartridge employs Carulite to convert CO to CO2. All materials are kept in place with an integrated 1.0 micron particulate after filter so the delivered air is free of any harmful gases, odors or particulate. These innovative cartridges are quick and easy to replace minimizing maintenance requirements.

The nano NBA is on the leading edge of breathing air technology, meeting and exceeding the most stringent global breathing air standards in a simple, reliable and cost effective design.

Optional Accessories

N/A nano-purification solutions has a wide range of options and upgrades to customize your B1 breathing air system including remote audible and visual alarms, free-standing CO monitors and all of the test kits, calibration kits and service kits you need to keep your B1 products working at their optimum level of performance.

Clean and Safe

N/A Many commercial and industrial processes can introduce contaminants into the air which threaten the health and safety of employees. It is important to choose a breathing air system that is safe, reliable, and high quality - yet cost effective to own and operate.

n-psi recognizes the importance of meeting international breathing air quality standards and protecting employees from hazardous environments. We have developed the B1 breathing air systems to meet and exceed global standards for breathing air quality in a comprehensive package with reliable performance.

Design

N/A Our experienced team of design engineers are always looking for new and unique technologies and products to bring you the highest level of performance and lowest overall operating cost.

Research and Development

N/A Our R&D team endeavor to provide solutions that go beyond developing an existing product. They are continually researching new technologies which can provide unique advantages over competitive offerings.

Manufacture

N/A Always reliable, nano B1 breathing air systems are manufactured in a state of the art facility to the highest standards of build quality to ensure reliability and high levels of performance.

Additional Information

N/A Leading edge technology and more than 100 years of experience…nano-purification solutions, your world-class provider of state-of-the-art compressed air and gas solutions to industry.

Our commitment at n-psi is to work alongside our customers and provide unique solutions with the highest quality products to solve your specific challenges.

A wealth of experience and leading edge products are only part of the equation. n-psi realize that world-class customer service is the most important component to any successful business.

Experience. Customer. Service…n-psi

If the compressed air is of sufficiently high quality and free of harmful gases, a filtration system to remove particulate, oil, odor and taste may be used in conjunction with a Carbon Monoxide (CO) monitor. These systems are available at a lower initial investment and meet many breathing air standards. If however, gases such as CO2 or CO may be present in dangerous levels, both filtration and purification are required.

nano-purification solutions is a leading manufacturer of breathing air products and has the experience to recommend, provide and support your breathing air system, whether you need a portable case, wall mounted panel or a complete modular purification system.

The nano B1 breathing air systems use the latest technology to provide clean, reliable and safe breathing air that meets or exceeds global standards. Contact us today and let our technical support department help you choose the breathing air system that best fits your needs.

reliability is built in... and backed by a 2 year warranty

Note

N/A If there is a known presence of harmful gases, please consult n-psi prior to selecting a breathing air product

  • Contact for intrinsically safe, integrated CO & O2 monitoring or any options or equipment not listed
  • quick-disconnect fittings for use in compressed breathing air systems shall be selected to prevent accidental connection to other sources of compressed gases