KB - Kaeser Oil Removal Filters
Kaeser - In Line Filtration
Used in contaminated compressed air lines (upstream of refrigeration dryers, for example) to remove aerosols and solid particles for ordinary air quality. Lower differential pressure and high filtration efficiency thanks to generously dimensioned filter housings, deeply pleated filter elements, flow-optimized element head and polyester drainage fleece.
- Maximum Liquid Loading: 1,000 ppm w/w
- Solid Particle Removal
- Oil Carry-Over: 0.01 mg/m^3
- Pressure Drop: Dry: 1 psi; Wet: 3 psi
Unit of Measure
Items |
/Asset/Filter_4.png F6KB KB - Kaeser Oil Removal Filters |
/Asset/Filter_4.png F9KB KB - Kaeser Oil Removal Filters |
/Asset/Filter_4.png F16KB KB - Kaeser Oil Removal Filters |
/Asset/Filter_4.png F26KB KB - Kaeser Oil Removal Filters |
/Asset/Filter_4.png F46KB KB - Kaeser Oil Removal Filters |
|||||
Air Flow at 100 psig | N/A 20 cfm | N/A 30 cfm | N/A 55 cfm | N/A 90 cfm | N/A 160 cfm | |||||
Connection Size | N/A 1/2 NPTF | N/A 3/4 NPTF | N/A 3/4 NPTF | N/A 1 NPTF | N/A 1 1/2 NPTF | |||||
Maximum Working Pressure | N/A 232 psig | |||||||||
Width | N/A 4 1/8 in | N/A 4 1/8 in | N/A 4 1/8 in | N/A 5 1/4 in | N/A 6.5 in | |||||
Height | N/A 12.1 in | N/A 12.1 in | N/A 13.4 in | N/A 15.4 in | N/A 16.3 in | |||||
Weight | N/A 5 lb | N/A 8 lb | N/A 9 lb | N/A 11 lb | N/A 11 lb | |||||
Standard Features of Filters | N/A Float Drain or Eco-Drain | |||||||||
Model Type | N/A Modular Type Housing | |||||||||
Liquid Removal | N/A 0 % | |||||||||
Maximum Liquid Loading | N/A 0 ppm w/w | |||||||||
Solid Particle Removal | N/A 0.01 µ | |||||||||
Oil Carry-Over | N/A | |||||||||
Pressure Drop - Dry | N/A .5 psi | |||||||||
Pressure Drop - Wet | N/A | |||||||||
Maximum Inlet Temperature | N/A 150 ºF | |||||||||
General Description |
N/A
Superior Filtration for Increased Productivity Kaeser Gives You the Air Quality You Require Ambient air contains contaminants that are drawn into the compressor. These contaminants are concentrated during compression and find their way into the compressed air system. A typical compressed air system is contaminated with abrasive solid particles such as dirt, rust and pipe scale, compressor lubricants, condensed water droplets, and oil and hydrocarbon vapors. Contaminated compressed air systems increase operating costs by robbing the air system of useful power. This results in reduced efficiency, damaged air operated equipment, higher maintenance and repair costs, reduced production caused by downtime, and increased product rejections. The properly sized and selected Kaeser filter(s) in conjunction with the appropriate dryer will remove these contaminants. This will allow the compressed air system to deliver the quality of air required for the particular application whether it’s plant air, instrument air, or breathing air. |
|||||||||
High Performance Filters and Separators | N/A Designed and developed using the latest innovations and manufacturing techniques, Kaeser filter housings are designed with larger flow areas to ensure low pressure drop and to provide easier installation, operation and maintenance. The result is consistent product quality while minimizing operating costs. | |||||||||
Kaeser Reduces the Cost of Compressed Air |
N/A
Kaeser filters remove more contaminants with less pressure drop. Compare the operating pressure drop of competitive brand filters and remember, for every extra 2 psi of pressure drop, power requirements increase by 1 %. With a complete selection of application-specific filter types, sizes, technical service and support, Kaeser offers a customized solution for all of your compressed air quality needs. |
|||||||||
Standard Features and Benefits |
N/A
|
|||||||||
Modular Housings for Flows Up to 780 scfm |
N/A
|
|||||||||
Enhanced Performance |
N/A
|
|||||||||
Premium Options |
N/A
- Operating time - Differential pressure - Filter type |
|||||||||
Note |
N/A
Maximum inlet temperature is 150 ºF. Specifications are subject to change without notice. |
|||||||||
Replaces | N/A KOR - 20 | N/A KOR - 35 | N/A KOR - 60 | N/A KOR - 100 | N/A KOR - 170 | |||||
Replacement Element Kit | N/A 901500.0 | N/A 901501.0 | N/A 901502.0 | N/A 901504.0 | N/A 901505.0 | |||||
|