Solberg’s HV Series bacterial filters for medical vacuum service are designed to offer industry leading pressure drop performance and meet demanding filtration requirements in accordance with current European and US medical vacuum standards:

ISO 7396-1:2016 Medical gas pipeline systems — Part 1 Pipeline systems for compressed medical gases and vacuum

NFPA 99:2018 Health Care Facilities Code

Unit of Measure
Items
Image

1" Medical Vaccum Filter

Image

1 1/4" Medical Vaccum Filter

Image

1 1/2" Medical Vaccum Filter

Image

2 " Medical Vaccum Filter

Image

2 1/2" Medical Vaccum Filter
Rarified Air Flow(5.4psi) N/A 110 cfm N/A 123 cfm N/A 123 cfm N/A 383 cfm N/A 383 cfm
Free Air Aspirated N/A 40 scfm N/A 45 scfm N/A 45 scfm N/A 140 scfm N/A 140 scfm
Inlet and Outlet Connection Size
N/A 1" NPSC N/A 1.25" NPSC N/A 1.5" NPSC N/A 2" NPSC N/A 2.5" NPTF
Dimension A N/A 22.5 in N/A 22.5 in N/A 22.5 in N/A 25.5 in N/A 25.5 in
Dimension B
N/A 1.5 in N/A 1.5 in N/A 1.5 in N/A 2 in N/A 2 in
Dimension C N/A 7 in N/A 7 in N/A 7 in N/A 9 in N/A 9 in
Dimension D N/A 10.375 in N/A 10.375 in N/A 10.375 in N/A 12.5 in N/A 12.5 in
Replacement Element Kit N/A UL896 N/A UL896 N/A UL896 N/A UL850/1 N/A UL850/1
HEPA Media Classification N/A E12
ULPA Media Classification N/A H14
TF Media Classification N/A E11
Shipping Weight N/A 15.00 lb N/A 15.00 lb N/A 15.00 lb N/A 19 lb N/A 19 lb
Maximum Rated Flow
N/A
Particle Removal at 100% Pleated Depth PP N/A
Minimum Removal Efficiency N/A 99.995 %
Maximum Continuous Operating Temperature N/A 220 ºF
Maximum Design Operating Pressure N/A
Initial Clean Pressure Differential N/A
Standard Inlet and Outlet Connections Materials N/A NPSC N/A NPSC N/A NPSC N/A NPSC N/A NPTF
Standard Media Element Materials N/A ULPA
Industry Standards/Certifications N/A
Applications N/A Industrial & Severe DutyVacuum Pumps & Systems: Roots, Rotary Vane, Screw, PistonVacuum Packaging EquipmentVacuum FurnaceBlowers: Side Channel & P.D.Vacuum LiftersIntake Suction FiltersFood IndustryWoodworking/RoutersAsh HandlingPrinting IndustryMedical/HospitalRemote Installations for Piston & Screw CompressorsPaper ProcessingWastewater AerationCement ProcessingBag House SystemsVacuum Vent BreathersChemical ProcessingFactory Automation EquipmentLeak Detection Systems
Additional Information N/A Gauge & Mounting BossAvailable with or without gauge. (Standard HV part number includes gauge.)For information on a unit without gauge, please contact the factory.Housings can be modified for mounting brackets by tapping the precastmounting bosses.
Note N/A